Battery Chargers

The following pages are in Adobe Acrobat. You will need the Acrobat Reader to view these pages
You can get the Free Reader by clicking here.
We will open these pages in a separate Browser window so you don't loose this page.

  Approvals Design Dim in mm
(w x h x d)
Nominal Volts
(V,DC)
Nominal Amps Input Volts
(V,AC)
Options*
    Sentinel Range

Sentinel  
UL, C-UL, CE Enclosed 105mm x 130mm x 72mm 12, 24 5, 10 120v, 240v MB, A
    Linear Equipment Range
Linear Equipment     Open Frame 85 x 108 x 115 6, 12, 24 1, 600mA 115V, 230V MB, PC
    Sentry Range
Sentry       Open Frame 113 x 90 x 105 12, 24 3, 5 115V, 230V, 277V CF, MB
Sentry    
 
Enclosed 140 x 250 x 270 12, 24 3, 5 115V, 230V, 277V CF, MB
Sentry     UL, C-UL, CE Open Frame 110 x 110 x 148 12, 24 3, 5, 10 120V, 240V CF, TC
Sentry     UL, C-UL, CE Enclosed 140 x 115 x 281 12, 24 3, 5, 10 120V, 230V CF, TC, MB
Sentry-7   CE Open Frame 110 x 110 x 148 12, 24 3, 5, 10 120V, 230V CF, TC, MB
Sentry-L   UL, C-UL, CE Enclosed 278 x 280 x 120 12, 24 3, 5, 10 120V, 230V CF, TC, MB, MCB
    Monitor Range
Monitor     Open Frame 118 x 170 x 160 12, 24 9, 15, 16, 30 110V, 240V CF, MB
Monitor     Enclosed 260 x 220 x 260 12, 24 9, 15, 16, 30, 60 110V, 240V CF, MB
    Guardian Range
Guardian   UL, C-UL, CE Open Frame 126 x 126 x 124 12, 24 10, 20 120V, 240V TC, A, MCB
Guardian   UL, C-UL, CE Enclosed 278 x 120 x 280 12, 24 10, 20 120V, 230V TC, A, MCB
    SM82
SM82 Switch     Open Frame 140 x 134 x 140 12, 24, 36, 48 5, 3, 2, 1.25 95-135V, 195-277V CF, MB, S, DIN, PC
SM82               Enclosed 140 x 270 x 270 12, 24, 36, 48 5, 3, 2, 1.25 95-135V, 195-277V CF, MB
    SM135
SM135 12/24     Open Frame 165 x 55 x 155 12/24 4.5 95-277V  
SM135 12/24     Enclosed 140 x 270 x 115 12/24 4.5 95-277V  
    SM2
SM2 160     Open Frame 100 x 50 x 160 12, 24 12, 6 95-277V S, MB, DIN
SM2 250     Open Frame 100 x 50 x 220 12, 24, 36, 48 17, 9, 6, 4.5 95-277V S, MB, OI, DIN, PC
    Voltage Monitoring
CVR 12 and CVR24       50 x 50 x 41 12, 24 12, 24 9-16V, 18-32V PB
LVD12 and LVD24       50 x 50 x 41 12, 24 12, 24 9-16V, 18-32V PB
    Key Start
Key Start 7200
(Standard)
Key Start 7201 (Overspeed)
  
  Enclosed 72 x 72 x 45 7-30 Crank: 16A @ 24V,DC Generator 70-300V @ 50-60 Hz Standard, Overspeed
* Options: A - NFPA 110 Alarms; CF - Charge Fail; DIN - DIN Rail Mount; MB - Manual Boost; MCB - Mains Circuit Breaker; OI - Output Inhibit; PB - Plug-In Base; PC - Protective Cover; S - Spade Connect; TC - Remote Temperature Compensation.

Home | About Us | Locations | Customer Service | Representatives | Meters | Transducers | Protective Relays
Transformers | Shunts | Cam Switches | Contactors | Resistors | Battery Chargers | Other Special DC